No. 8 Wyndham Street, Far East Exchange Builiding, Central Hong Kong
Project Items
- P&T-150-001 Topographical survey
- P&T-150-002 #8 Wyndham Street Far East Exchange Building redevelopment main contract tender drawing
- P&T-150-003 #8 Wyndham Street Far East Exchange Building redevelopment curtain wall subcontract tender drawing
- P&T-150-004 Far East Exchange Building Hong Kong curtainwall drawing: 3th floor to roof
- P&T-150-005 Basement plan
- P&T-150-006 Basement plan
- P&T-150-007 Basement plan
- P&T-150-008 Ground floor plan
- P&T-150-009 Ground floor plan
- P&T-150-010 Ground floor plan
- P&T-150-011 Part plan +19.70 & part plan +22.40
- P&T-150-012 Part plan +19.70 & part plan +22.40
- P&T-150-013 Part plan +19.70 & part plan +22.40
- P&T-150-014 2nd floor plan (mechanical floor plan)
- P&T-150-015 2nd floor plan (mechanical floor plan)
- P&T-150-016 2nd floor plan (mechanical floor plan)
- P&T-150-017 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-018 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-019 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-020 26th floor plan
- P&T-150-021 26th floor plan
- P&T-150-022 26th floor plan
- P&T-150-023 27th floor plan
- P&T-150-024 27th floor plan
- P&T-150-025 27th floor plan
- P&T-150-026 Mechanical roof plan
- P&T-150-027 Mechanical roof plan
- P&T-150-028 Mechanical roof plan
- P&T-150-029 Roof plan
- P&T-150-030 Roof plan
- P&T-150-031 Roof plan
- P&T-150-032 Section A-A
- P&T-150-033 Section A-A
- P&T-150-034 Section A-A
- P&T-150-035 Section B-B
- P&T-150-036 Section B-B
- P&T-150-037 Section B-B
- P&T-150-038 Section C-C
- P&T-150-039 Section C-C
- P&T-150-040 Section C-C
- P&T-150-041 On Lan Street elevation
- P&T-150-042 On Lan Street elevation
- P&T-150-043 On Lan Street elevation
- P&T-150-044 Wyndham Street elevation
- P&T-150-045 Wyndham Street elevation
- P&T-150-046 Wyndham Street elevation
- P&T-150-047 North-east elevation
- P&T-150-048 North-east elevation
- P&T-150-049 North-east elevation
- P&T-150-050 South-east elevation
- P&T-150-051 South-east elevation
- P&T-150-052 South-east elevation
- P&T-150-053 Key plan & general notes
- P&T-150-054 Site area / dedicated area calculation
- P&T-150-055 Plot ratio & site coverage calculation
- P&T-150-056 Plot ratio & site coverage calculation
- P&T-150-057 Plot ratio & site coverage calculation
- P&T-150-058 Building area calculation (1)
- P&T-150-059 Building area calculation (2)
- P&T-150-060 G.F.A. calculation
- P&T-150-061 G.F.A. calculation
- P&T-150-062 G.F.A. calculation
- P&T-150-063 Usable floor area calculation (1)
- P&T-150-064 Usable floor area calculation (2)
- P&T-150-065 Schedules & misc. calculation
- P&T-150-066 Schedules & misc. calculation
- P&T-150-067 Schedules & misc. calculation
- P&T-150-068 3rd-27th floor plans
- P&T-150-069 Roof plan
- P&T-150-070 Curtainwall elevation
- P&T-150-071 Curtainwall elevation
- P&T-150-073 Curtainwall elevation
- P&T-150-074 Curtainwall elevation
- P&T-150-075 Curtainwall details
- P&T-150-076 Curtainwall details
- P&T-150-077 Curtainwall details
- P&T-150-078 Curtainwall details
- P&T-150-079 Curtainwall details
- P&T-150-080 Curtainwall details
- P&T-150-081 Curtainwall details
- P&T-150-082 Curtainwall details
- P&T-150-083 Curtainwall details
- P&T-150-084 Curtainwall details
- P&T-150-085 Curtainwall details
- P&T-150-086 Curtainwall details
- P&T-150-087 Curtainwall details
- P&T-150-088 Curtainwall details
- P&T-150-089 Curtainwall details
- P&T-150-090 Curtainwall details
- P&T-150-091 Curtainwall details
- P&T-150-092 Standard details
- P&T-150-093 Bored pile layout plan
- P&T-150-094 Loading schedule and bored piled details
- P&T-150-095 Monitoring and instrumentation
- P&T-150-096 Pipe pile wall and grout curtain layout plan (sheet 1 of 2)
- P&T-150-097 Pipe pile wall and grout curtain layout plan (sheet 2 of 2)
- P&T-150-098 Shoring layout plan (sheet 1 of 2)
- P&T-150-099 Shoring layout plan (sheet 2 of 2)
- P&T-150-100 Excavation and shoring procedure
- P&T-150-101 Shoring connection details (sheet 1 of 2)
- P&T-150-102 Shoring connection details (sheet 2 of 2)
- P&T-150-103 Pile cap layout
- P&T-150-104 Starter bar details for walls & columns
- P&T-150-105 Pile cap details
- P&T-150-106 Ground floor framing plan, basement framing plan
- P&T-150-107 2/F framing plan, part plan level +18.00, part plan level +22.40
- P&T-150-108 3/F to 26/F framing plan
- P&T-150-109 27/F, 28/F and roof framing plan
- P&T-150-110 Ground floor slab details
- P&T-150-111 2/F to 26/F slab details
- P&T-150-112 27/F, 28/F and roof slab details
- P&T-150-113 Ground & 1st floor beam details : sheet 1 of 2
- P&T-150-114 Ground & 1st floor beam details : sheet 2 of 2
- P&T-150-115 2nd floor beam details
- P&T-150-116 3rd-25th floor beam details : sheet 1 of 2
- P&T-150-117 3rd-25th floor beam details : sheet 2 of 2
- P&T-150-118 26th-27th floor beam details
- P&T-150-119 Mechanical roof & roof beam details : sheet 1 of 2
- P&T-150-120 Mechanical roof & roof beam details : sheet 2 of 2
- P&T-150-121 Columns details
- P&T-150-122 Wall details (W1-W4) : sheet 1 of 3
- P&T-150-123 Wall details (W1-W4) : sheet 2 of 3
- P&T-150-124 Wall details (W1-W4) : sheet 3 of 3
- P&T-150-125 Wall details (W5, W6, W8, W10 & W11) : sheet 1 of 4
- P&T-150-126 Wall details (W5, W6, W8, W10 & W11) : sheet 2 of 4
- P&T-150-127 Wall details (W5, W6, W8, W10 & W11) : sheet 3 of 4
- P&T-150-128 Wall details (W5, W6, W8, W10 & W11) : sheet 4 of 4
- P&T-150-129 Elevation of wall - W7 & W7A
- P&T-150-130 Wall details (W9)
- P&T-150-131 Basement wall details
- P&T-150-132 Wall beam details : sheet 1 of 2
- P&T-150-133 Wall beam details : shee 2 of 2
- P&T-150-134 Stair no. 1 & 3 details
- P&T-150-135 Stair no. 2 & 4 details
- P&T-150-136 Stair details entrance and stair no. 5
- P&T-150-137 Water tank and manhole details
- P&T-150-138 Grout curtain-field pumping test
- P&T-150-139 Hoarding layout plan & elevation
- P&T-150-140 Hoarding section and typical details
- P&T-150-141 Basement plan
- P&T-150-142 Basement plan
- P&T-150-143 Basement plan
- P&T-150-144 Basement plan
- P&T-150-145 Ground floor plan
- P&T-150-146 Ground floor plan
- P&T-150-147 Ground floor plan
- P&T-150-148 Ground floor plan
- P&T-150-149 Part plan +19.70 & part plan +22.40
- P&T-150-150 Part plan +19.70 & part plan +22.40
- P&T-150-151 Part plan +19.70 & part plan +22.40
- P&T-150-152 2nd floor plan (mechanical floor plan)
- P&T-150-153 2nd floor plan (mechanical floor plan)
- P&T-150-154 2nd floor plan (mechanical floor plan)
- P&T-150-155 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-156 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-157 3rd-25th floor plan (typical floor plan) (level 32.40 to 120.40)
- P&T-150-158 26th floor plan
- P&T-150-159 26th floor plan
- P&T-150-160 26th floor plan
- P&T-150-161 26th floor plan
- P&T-150-162 27th floor plan
- P&T-150-163 27th floor plan
- P&T-150-164 27th floor plan
- P&T-150-165 27th floor plan
- P&T-150-166 28th floor plan
- P&T-150-167 Mechanical roof plan
- P&T-150-168 Mechanical roof plan
- P&T-150-169 Mechanical roof plan
- P&T-150-170 Roof plan
- P&T-150-171 Roof plan
- P&T-150-172 Roof plan
- P&T-150-173 Roof plan
- P&T-150-174 Section A-A
- P&T-150-175 Section A-A
- P&T-150-176 Section A-A
- P&T-150-177 Section B-B
- P&T-150-178 Section B-B
- P&T-150-179 Section B-B
- P&T-150-180 Section C-C
- P&T-150-181 Section C-C
- P&T-150-182 Section C-C
- P&T-150-183 On Lan Street elevation
- P&T-150-184 On Lan Street elevation
- P&T-150-185 On Lan Street elevation
- P&T-150-186 Wyndham Street elevation
- P&T-150-187 Wyndham Street elevation
- P&T-150-188 Wyndham Street elevation
- P&T-150-189 North-east elevation
- P&T-150-190 North-east elevation
- P&T-150-191 North-east elevation
- P&T-150-192 South-east elevation
- P&T-150-193 South-east elevation
- P&T-150-194 South-east elevation
- P&T-150-195 Typical floor pattern at 3/F to 25/F (odd no. only)
- P&T-150-196 Elevation of stone pattern at ground floor
- P&T-150-197 Elevation of stone pattern at ground floor
- P&T-150-198 Elevation of stone pattern at ground floor
- P&T-150-199 Elevation of stone pattern at ground floor
- P&T-150-200 Elevation of external wall stone pattern
- P&T-150-201 Elevation of external wall stone pattern
- P&T-150-202 Staircase 1 & 3
- P&T-150-203 Staircase 1 & 3
- P&T-150-204 Staircase 1 & 3 section A-A
- P&T-150-205 Staircase 1 & 3 section A-A
- P&T-150-206 Staircase 2 & 4
- P&T-150-207 Staircase 2 & 4
- P&T-150-208 Staircase 2 & 4
- P&T-150-209 Staircase 2 & 4 section B-B
- P&T-150-210 Staircase 2 & 4 section B-B
- P&T-150-211 Staircase (entrance) & staircase 5
- P&T-150-212 Staircase (entrance) & staircase 5
- P&T-150-213 Smoke lobby (ground floor)
- P&T-150-214 Smoke lobby (ground floor)
- P&T-150-215 Protected lobby (ground floor)
- P&T-150-216 Protected lobby (ground floor)
- P&T-150-217 Smoke lobby (typical floor)
- P&T-150-218 Smoke lobby (typical floor)
- P&T-150-219 Protected lobby (typical floor)
- P&T-150-220 Protected lobby (typical floor)
- P&T-150-221 Smoke lobby (27th floor)
- P&T-150-222 Smoke lobby (27th floor)
- P&T-150-223 Male lavatory (typical floor)
- P&T-150-224 Male lavatory (typical floor)
- P&T-150-225 Male lavatory (typical floor)
- P&T-150-226 Male lavatory (typical floor)
- P&T-150-227 Male lavatory (typical floor)
- P&T-150-228 Female lavatory (typical floor)
- P&T-150-229 Female lavatory (typical floor)
- P&T-150-230 Female lavatory (typical floor)
- P&T-150-231 Female lavatory (typical floor)
- P&T-150-232 Disable lavatory (typical floor)
- P&T-150-233 Disable lavatory (typical floor)
- P&T-150-234 Disable lavatory (typical floor)
- P&T-150-235 Lavatory (27th floor)
- P&T-150-236 Male lavatory (27th floor)
- P&T-150-237 Male lavatory (27th floor)
- P&T-150-238 Female lavatory (27th floor)
- P&T-150-239 Female lavatory (27th floor)
- P&T-150-240 Ground floor reflected ceiling plan
- P&T-150-241 Ground floor reflected ceiling plan
- P&T-150-242 Note sheet